Verify

Returning Candidate?

Source Inspector

Source Inspector

Req No. 
2018-5716
Job Locations 
US-CA-South El Monte
Category 
Verification
Type 
Project Specialist
Frequency (Hours per Week) 
40
Duration (Days) 
7

More information about this job

Overview

Location details (name, city and country):

El Monte, East LA.

Specific products / commodity details:

3 foot x 10 foot extruded titanium bar

Describe the activity and primary duties being requested:

3rd Party independent inspection for straightness, flatness & twist.

Measure, analyze and complete inspection reports.

Describe the ideal skills, experience and qualifications to perform this activity:

Skills in measurement and analysis, experience with taper & shim measurements.

Detail any specific Standards or Specification applicable:

Inspection guides to be provided by customer, they conform to AMS2245B (Tolerances, Titanium and Titanium Alloy Extruded Bars, Rods, and Shapes).

Identify frequency of assignment (hours per week or days per month):

Full time for approx. 1 to 1.5 weeks

Identify duration of assignment (number of weeks or months)

40 to 50 hours

Additional information:

Civil Product

10x measurements per bar

Customer has sent approx. 250 bars over to their customer. A quality concern has been raised, 3rd Party inspection has been proposed to resolve this.

Estimated start date:

By end of March